Coolant Compatibility
JONSN Micro Gear Pumps — Coolant Preparation and Central Management Scheme
Base fluid ratio · Inhibitor top-up · Biocide dosing · pH regulation · Waste fluid recovery — from fresh fluid preparation to aged fluid treatment, the whole life cycle of the coolant is managed precisely

Battery cooling, e-drive oil cooling, supercharging pile liquid cooling, charging gun and cable cooling, refrigerant direct cooling top-up — the diversification of the new energy thermal management system has turned the coolant from "one liquid per vehicle" into a complex system of multiple circuits, multiple formulations and multiple batches. A passenger car leaving the factory has to be filled with battery coolant, e-drive coolant and heat pump refrigerant / lubricating oil; a supercharging station has to prepare centrally and manage several hundred litres of coolant over long-term running; the coolant of a storage container has to be regulated continuously for 5–8 years without being replaced.
The coolant is not "filled once and never touched again" — the oxidation of glycol at high temperature produces acid and requires pH buffering and inhibitor top-up; long stagnation breeds bacteria and algae and requires a biocide; the slight leakage of refrigerant requires online top-up; and the coolant has to be safely recycled when its life ends.
Industry Pain Points
JONSN Solution: Five Processes, Whole-Life-Cycle Management
MRA for the main flow ratio (100–2000 mL/min), MPG for the micro additives (40 μl/r)
±0.2% ratio accuracy, consistent freezing point / boiling point / conductivity between batches, ready to integrate into the filling station of an OEM
Pulsed precise top-up, 5–50 ml per shot, eliminating the "add a scoop by feel"
PEEK + ceramic fully chemically inert to OAT / borate / silicate inhibitors
μL-level intermittent dosing, maintaining a 10–50 ppm inhibitory concentration, no waste and no side reaction
PTFE sealing fully resistant, no swelling with isothiazolinone / glutaraldehyde / QAC biocide
PID closed loop regulating pH within ±0.2, the corrosion rate of the aluminium cold plate reduced by more than 90%
PEEK pump body with zero metal dissolution, not interfering with the measurement baseline of the conductivity / pH sensors
0.8–48 L/min large-flow rapid recovery, excellent passability of particulates in the waste fluid
Fully magnetic, zero dripping, environmental compliance in hazardous waste transfer
Quick-release pump head flushed and reused in 3 minutes, no cross contamination between waste fluid batches
Product Selection Quick Reference
| Management Step | Medium | Recommended Series | Key Index |
|---|---|---|---|
| Base fluid ratio (main flow) | Glycol + deionized water | MRA | 100–2000 mL/min, ±0.5% ratio accuracy |
| Base fluid ratio (additives) | Inhibitor / defoamer / fluorescent agent | MPG | 40 μl/r, precise ppm-level injection |
| Online inhibitor top-up | OAT / silicate inhibitor | MPG | 5–50 ml single top-up, extends the fluid life by 2–3 years |
| Micro biocide dosing | Isothiazolinone / glutaraldehyde | MPG | μL-level intermittent dosing, maintaining 10–50 ppm |
| Online pH regulation | Dilute KOH solution / organic amine | MPG | PID closed loop, pH ±0.2, aluminium cold plate protection |
| Waste fluid recovery | Aged glycol coolant (with particulates) | MRC / MRE | 0.8–48 L/min, good particulate passability, zero dripping |