Industry Applications · Coolant Preparation & Central Management

JONSN Micro Gear Pumps — Coolant Preparation and Central Management Scheme

Base fluid ratio · Inhibitor top-up · Biocide dosing · pH regulation · Waste fluid recovery — from fresh fluid preparation to aged fluid treatment, the whole life cycle of the coolant is managed precisely

MRA · Main flow ratio metering
MPG · Micro additive dosing
MRC / MRE · Waste fluid recovery
Repeatability ±0.2%
ppm-level metering, 40 μl/r displacement
Zero leakage, fully inert PEEK flow path
Excellent passability of particulates
矩形 6备份 22.jpg
Industry Background

Battery cooling, e-drive oil cooling, supercharging pile liquid cooling, charging gun and cable cooling, refrigerant direct cooling top-up — the diversification of the new energy thermal management system has turned the coolant from "one liquid per vehicle" into a complex system of multiple circuits, multiple formulations and multiple batches. A passenger car leaving the factory has to be filled with battery coolant, e-drive coolant and heat pump refrigerant / lubricating oil; a supercharging station has to prepare centrally and manage several hundred litres of coolant over long-term running; the coolant of a storage container has to be regulated continuously for 5–8 years without being replaced.

The coolant is not "filled once and never touched again" — the oxidation of glycol at high temperature produces acid and requires pH buffering and inhibitor top-up; long stagnation breeds bacteria and algae and requires a biocide; the slight leakage of refrigerant requires online top-up; and the coolant has to be safely recycled when its life ends.

Industry Pain Points

① The accuracy of the base fluid ratio sets the performance baseline
The best ratio of glycol to water is usually 50:50 by volume, and a deviation of ±2% raises the freezing point by 3–5 °C or lowers the thermal conductivity. The dosage of inhibitor, defoamer and fluorescent leak detector is only at the ppm to per-mille level, and the consistency of manual proportioning is hard to guarantee. A centralized coolant filling station of an OEM handles several thousand litres of mixed fluid every day, and the ratio fluctuation between batches directly affects the freezing point consistency and the corrosion protection capability of the cooling system of the vehicles leaving the factory.
② Inhibitor consumption is invisible, top-up is done by feel
Organic acid type inhibitors (OAT) are consumed continuously in the high-temperature cycle, but the consumption rate is hard to monitor online. Most operation scenarios adopt a coarse "periodic fluid change" strategy — the coolant is discarded long before it fails, or it keeps running in a failed state, which corrodes the micropores of the aluminium cold plate. Precise on-demand inhibitor top-up can extend the coolant life by 2–3 years, but there is no reliable means of micro metering and pumping.
③ pH drift is an invisible killer of the aluminium cold plate
The oxidation products of glycol (oxalic and formic acid) make the pH of the coolant fall slowly from the factory value of 8.0–10.5 to below 7.0. In an acidic environment the corrosion rate of the micro channels of the aluminium cold plate (bore 0.3–0.8 mm) grows exponentially — once micro perforation occurs the cold plate is scrapped directly, and the replacement cost far exceeds that of the pump itself. pH regulation requires real-time online dosing of the buffer, but the dosage is extremely small (mL per hundred litres of coolant), and ordinary metering pumps lack the accuracy.
④ Waste fluid recovery: the environmental red line and the cost bottom line
Glycol is listed in the National Hazardous Waste Catalogue (HW06), and waste coolant must not be discharged directly. Centralized recovery requires pumping the aged fluid from the vehicles, charging piles and storage containers into a storage tank and then transferring it to a qualified processor. The waste fluid often contains particulates, oil sludge and metal debris, so the recovery pump has to tolerate a turbid medium without clogging or leaking — a task one order of magnitude harder than conveying fresh fluid.

JONSN Solution: Five Processes, Whole-Life-Cycle Management

Process 1
Base fluid ratio
The MPG series (displacement 40–80 μl/r, flow 1–280 mL/min) and the MRA series (100–2000 mL/min) form a dual-pump ratio station: the large-flow pump (MRA) injects the glycol and deionized water main streams quickly into the mixing tank at 50:50, while the micro pump (MPG) precisely injects the inhibitor, defoamer and fluorescent agent at the ppm level. The repeatability is ±0.2%, which achieves a ratio deviation of ±1% between batches. The all-PEEK flow path with zero metal ion dissolution does not contaminate the newly mixed coolant.
  • MRA for the main flow ratio (100–2000 mL/min), MPG for the micro additives (40 μl/r)

  • ±0.2% ratio accuracy, consistent freezing point / boiling point / conductivity between batches, ready to integrate into the filling station of an OEM

Process 2
Online inhibitor top-up
An MPG micro metering pump and an inhibitor tank are installed on a bypass of the coolant circulation line, and the top-up is triggered on demand according to the feedback signal of the conductivity / pH sensor. A single top-up is 5–50 ml, and the displacement of 40 μl/r makes sure that every pulse is one precisely metered top-up, with no overdose and no shortfall. The inhibitor concentration verified by periodic sampling always stays inside the process window, and the usable life of the coolant is extended from the 3 years of periodic fluid change to 5–8 years.
  • Pulsed precise top-up, 5–50 ml per shot, eliminating the "add a scoop by feel"

  • PEEK + ceramic fully chemically inert to OAT / borate / silicate inhibitors

Process 3
Micro biocide dosing
During the long stagnation periods of a storage container or a charging pile (night time, non-charging periods), bacteria and algae breed easily in the coolant, and especially above 30 °C in summer they multiply fast. The MPG series injects a non-oxidizing biocide (such as isothiazolinone) intermittently with μL-level accuracy, on a time-based or temperature-triggered strategy. The ultra-low displacement keeps the biocide at an effective concentration of 10–50 ppm instead of an overdose — an overdose would instead accelerate the consumption of the inhibitor.
  • μL-level intermittent dosing, maintaining a 10–50 ppm inhibitory concentration, no waste and no side reaction

  • PTFE sealing fully resistant, no swelling with isothiazolinone / glutaraldehyde / QAC biocide

Process 4
Online pH regulation
A pH sensor monitors the acidity of the coolant in real time; when the pH falls to the threshold (for example below 7.5), the MPG metering pump precisely injects an alkaline buffer (such as a dilute potassium hydroxide solution or an organic amine buffer) at a μL/s rate, and a closed-loop PID strategy pulls the pH back into the safe range of 8.0–9.0. The PEEK + ceramic flow path tolerates long-term contact with the alkaline buffer and introduces no metal ions that would interfere with the pH reading a second time.
  • PID closed loop regulating pH within ±0.2, the corrosion rate of the aluminium cold plate reduced by more than 90%

  • PEEK pump body with zero metal dissolution, not interfering with the measurement baseline of the conductivity / pH sensors

Process 5
Waste fluid recovery
The MRC series (0.8–14 L/min) and the MRE series (4–48 L/min) magnetic gear pumps take on the recovery and conveying of aged coolant from the vehicles, storage cabinets and charging piles to the waste fluid tank. The positive-displacement volumetric principle gives the pump excellent passability for the metal wear particles, oil sludge and polymer flocs in the waste fluid, so it neither clogs nor seizes. The fully magnetic sealing achieves zero dripping when conveying hazardous waste liquid, which satisfies the environmental compliance requirement. The quick-release pump head design allows the waste fluid pump to be flushed quickly and reused after a fluid change.
  • 0.8–48 L/min large-flow rapid recovery, excellent passability of particulates in the waste fluid

  • Fully magnetic, zero dripping, environmental compliance in hazardous waste transfer

  • Quick-release pump head flushed and reused in 3 minutes, no cross contamination between waste fluid batches

Core Value

1
Five processes of the whole life cycle, one pump platform covers all
From new fluid ratio to waste fluid recovery, MPG (micro metering) + MRA (small and medium flow) + MRC/MRE (large-flow recovery) form a complete pumping matrix. On the same platform, with the same interfaces and the same control system, a centralized coolant management station does not have to deal with several pump suppliers.
2
ppm-level additive metering, extending the coolant life by 2–3 times
The inhibitor is no longer consumed coarsely by "periodic fluid change" but is topped up in real time and in micro quantities according to the feedback of the pH / conductivity sensor. The biocide is dosed accurately at the μL level instead of poured into the whole tank. The coolant changes from a 3-year replacement into 5–8 years of online maintenance, directly saving material cost and the labour of the fluid change.
3
Closed-loop pH regulation, the corrosion risk of the aluminium cold plate driven to zero
The corrosion of the micro channels of the aluminium cold plate is irreversible and cannot be repaired. The closed-loop scheme of the pH sensor + the MPG pump + PID control holds the pH fluctuation within ±0.2, so that the cold plate has no acidic corrosion perforation over its whole life cycle — this is the most hidden and the most expensive value line of the coolant management system.
4
Zero leakage and fully inert materials, the coolant itself is not contaminated
A pump that manages the quality of the coolant must not itself become a contamination source. The all-PEEK + ceramic + PTFE flow path has zero metal dissolution, does not affect the measurement baseline of the conductivity and pH, and does not consume the inhibitor — the pump is part of the solution, not a new problem.
5
Waste fluid recovery integrated, both environmental and economic return
The disposal cost of glycol hazardous waste rises year by year, and centralized recovery is not only compliant but can also hand the waste fluid to a regeneration processor for refining and reuse. The JONSN recovery pump works on three lines — particulate passability, zero dripping and quick-release cleaning — which turns waste fluid recovery from a "headache step" into a standard process step.
6
Traceable data, meeting IATF 16949 manufacturing process control
The linear speed-flow relation of the gear pump can output a flow pulse signal directly, and the ratio records and the top-up records can be integrated into the MES / SCADA system. The coolant management stations of OEMs and Tier 1 suppliers meet the IATF 16949 process traceability requirement.

Please Contact Us!

ADDRESS

Building A3, Qiuyue Science and Technology Park, Ganzhou Economic and Technological Development Zone, Jiangxi Province

Tel.

0086-21-34720020

Follow Us

CopyRight © 2026 - Shanghai JONSN Fluid Equipment Co., Ltd.  All rights reserved  Sitemap All tags  Designed by Zhonghuan Internet
WHAT ARE YOU LOOKING FOR?
*
This field is required
Total quantity you need
*
This field is required
*
This field is required
Email format error
Due to email instability, you might miss our correspondence. Please provide your phone number for alternative contact.
This field is required
Telephone information is wrong!
Send Message
Get Custom Fluid Dosing Selection Solution
Starting a new project? Contact us for tailored pump solutions — from inlet specs and pipe sizing to motor matching and drawings — designed to fit your working conditions and accelerate your R&D cycle.
Company Name
*
This field is required
Email
*
This field is required
Email format error
Phone
This field is required
Telephone information is wrong!
WhatsApp
Message
*
This field is required
Send Message