Semiconductors & ElectronicsSemiconductors & Electronics
Semiconductors & Electronics
HomeCaseSemiconductors & ElectronicsElectronic-Grade Chemical Delivery

Electronic-Grade Chemical Delivery

2026-11-20
View:15
Applications · Electronic Chemical Delivery

Electronic Chemical Delivery: Constant-Pressure Supply and Precise Metering of Aggressive Media with JONSN Magnetic Gear Pumps

For semiconductor and electronics manufacturing, this solution analyses the technical requirements of constant-pressure supply loops and precise metering loops against the four operating conditions of strong corrosivity, ultra-purity, constant pressure and zero leakage — and presents the JONSN-MPG and JONSN-MRA (HC276) magnetic gear pump product solutions, typical loop configurations and selection method.

Minimum flow 1 ml/min (order of magnitude)
Max working pressure 10 bar
Flow control accuracy ±0.5%
Zero leakage path · magnetic coupling, no dynamic seal
矩形 6备份 2.jpg

Two Core Loops in Electronic Chemical Delivery

In semiconductor processes and electronics manufacturing, electronic grade chemicals are one of the key determinants of product yield. Whether wet etching, cleaning, developing or CMP polishing, strongly corrosive chemicals such as sulfuric acid, hydrochloric acid, hydrofluoric acid and phosphoric acid must be delivered stably from the storage vessel to the process point under strictly controlled conditions. On this invisible delivery chain, the constant-pressure supply loop and the precise metering loop are the two core links, and the circulation pump is the "heart" that decides whether these links can run stably over the long term.

LOOP 01
Constant-Pressure Supply Loop
The constant-pressure supply loop transfers chemicals stably from the tank or drum source to the pressure buffer device of the process equipment, keeping line pressure constant. When the process equipment takes liquid at multiple points, the supply pump must start-stop or modulate frequently according to level and pressure changes, guaranteeing that every take-off point receives chemicals at consistent pressure and flow. Once pressure fluctuates, spray flow and etch uniformity drift accordingly, directly affecting process repeatability.
LOOP 02
Precise Metering Loop
The precise metering loop performs accurate proportioning and quantitative dosing of chemicals — for example etchant blending, additive replenishment in cleaning baths, and circulating supply of CMP slurry. All of these require the pump to complete low-volume, controllable medium transfer with high repeatability. Insufficient metering accuracy causes ratio drift: at best chemical waste, at worst batch-level process excursions.
The common operating conditions of the two loops are obvious: the media are mostly strongly corrosive electronic grade chemicals, cleanliness requirements are extremely high, and strict indices apply to pressure stability and transfer accuracy.

Four Operating Challenges: Corrosion, Purity, Pressure, Leakage

1
Strong Corrosivity
Electronic grade sulfuric acid, hydrochloric acid, hydrofluoric acid, phosphoric acid and various etchants are extremely corrosive to ordinary metals. If wetted parts are improperly selected, the result is metal ions leaching into the chemical at best, or perforation by corrosion within a short period at worst — causing leakage and safety accidents. Conventional stainless steel pumps can hardly work in such media over the long term.
2
Ultra-Purity
Metal-ion contamination control for semiconductor grade chemicals is counted at ppb and even ppt level. Any wear particle or dissolved ion during transfer directly contaminates the chemical. Conventional mechanical seal structures suffer from sealing-face wear, and the micro-particles generated by dynamic sealing are an unacceptable risk for ultra-pure media.
3
Constant Pressure
The inherent flow pulsation of a gear pump, if poorly controlled, creates pressure fluctuation in the line and affects the stability of spray and etch steps. Meanwhile, the pressure repeatability of the pump during long-term continuous operation directly determines the regulation quality of the supply loop.
4
Zero Leakage
Zero leakage is the fourth threshold and the safety baseline. Once a strongly corrosive chemical leaks, it not only loses medium and corrodes equipment, but also brings personnel injury and environmental risk. Pump types with dynamic seals embed the leakage hazard inside the system, while the chemical-leakage prevention level of wet process areas keeps rising.
Against these four challenges, magnetic gear pumps have become the mainstream technical route for electronic chemical transfer — yet the internal material selection, gear precision and magnetic circuit design still directly determine actual performance.

Typical Application Loops

矩形 6备份 3.jpg
Tank / Drum Source
↓
【 JONSN-MPG Magnetic Gear Pump 】
↓
Pressure Buffer / Back-pressure Regulation Unit
↓
Process Take-off Point
Constant-pressure supply loop configuration: the pump runs continuously or supplies intermittently according to the line pressure signal, keeping line pressure inside the set window. Thanks to low-pulsation output, the buffer unit can be correspondingly downsized and the system responds faster.
Precise metering loop configuration: metering pump (JONSN-MPG or JONSN-MRA series) → flow verification / feedback unit → mixing or dosing point. The pump starts-stop or varies speed according to the set quantity, and precise proportioning is achieved with cumulative flow feedback. Ceramic gears and inert wetted materials guarantee long-term stability of metering characteristics when conveying aggressive additives.
In addition, in CMP slurry circulation, etchant spray circulation, sampling and online analysis pretreatment branches, JONSN magnetic gear pumps also serve as circulation and transfer units, covering multiple links of the electronics wet process.

Selection Guide

Table 1 · JONSN magnetic gear pump selection reference for electronic chemical transfer.

ModelWetted MaterialsFlow Accuracy / PulsationMax PressureApplication Scenario
JONSN-MPG SeriesStainless steel / corrosion-resistant alloy (selected by medium)Accuracy ±0.5%, low pulsation10 barUltra-pure chemical constant-pressure supply, small-volume metering, solvent media
JONSN-MRA Series (HC276)PTFE liner + HC276 Hastelloy + ceramic gearsAccuracy ±0.3%~0.5%Configured per dutyConstant-pressure and quantitative transfer of strong acid / etchant and other highly corrosive media

When selecting, confirm in the following order:

Step 01
Medium Chemistry
Define the chemical composition and concentration of the medium to determine the wetted materials (for HF-based systems, prefer PTFE / ceramic combinations).
Step 02
Flow Range & Accuracy
Confirm the required flow range and metering accuracy, then select the matching model and drive configuration.
Step 03
Line Resistance & Pressure
Review line resistance and take-off point pressure requirements to determine the pump working pressure and motor power.
Step 04
Installation & Cleanliness
Combine installation space and cleanliness-grade requirements to determine the interface form and integration method.

Please Contact Us!

ADDRESS

Building A3, Qiuyue Science and Technology Park, Ganzhou Economic and Technological Development Zone, Jiangxi Province

Tel.

0086-21-34720020

Follow Us

CopyRight © 2026 - Shanghai JONSN Fluid Equipment Co., Ltd.  All rights reserved  Sitemap All tags  Designed by Zhonghuan Internet
WHAT ARE YOU LOOKING FOR?
*
This field is required
Total quantity you need
*
This field is required
*
This field is required
Email format error
Due to email instability, you might miss our correspondence. Please provide your phone number for alternative contact.
This field is required
Telephone information is wrong!
Send Message
Get Custom Fluid Dosing Selection Solution