Immersion Cooling
JONSN Micro Gear Pumps — Immersion Liquid Cooling Scheme
Fluorinated fluid circulation · Condensate return · Filtration and purification — PEEK fully chemically inert, zero swelling under long-term immersion

Immersion liquid cooling is one of the mainstream technology paths for data centres to deal with the heat dissipation of high-density GPU / AI clusters. The complete server or blade is immersed directly in the dielectric coolant (usually a fluorinated fluid such as the 3M Novec series or an engineering fluid); the liquid absorbs the heat of the chips and is cooled by an external CDU and circulated back. Compared with cold plate liquid cooling, immersion achieves 100% heat contact, the PUE can be as low as 1.02–1.05, and the cooling capacity of a single rack breaks through 100 kW.
The core liquid path of an immersion system contains three fluid processes: the circulation of the fluorinated fluid from the immersion tank to the CDU → the return of the condensate to the immersion tank → the online filtration and purification removing particulates and decomposition products. Each of them places strict requirements on the chemical inertness, the flow accuracy and the long-term immersion resistance of the pump.
Industry Pain Points
JONSN Solution: Three-Ring Liquid Path, Fully Chemically Inert
Main circulation flow 0.4–14 L/min, a single pump serves one tank up to a small and medium immersion cluster
Pressure rating 4–6 MPa, overcoming the pressure drop of the long line from the CDU heat exchanger to the immersion tank
Positive displacement volumetric principle, the flow is not affected by the viscosity-temperature change of the fluorinated fluid
Stable return flow without pulsation, keeping the liquid level in the immersion tank controllable within ±2 mm
Fully magnetic sealing, eliminating the slow volatilization of the fluorinated fluid and the ingress of external moisture
Bypass filtration running continuously 24×7, 20,000 hours maintenance-free matching the continuous running rhythm of the data centre
PEEK fully inert to HF, generating no secondary metal ion contamination
Product Selection Quick Reference
| Liquid Path Function | Medium | Recommended Series | Key Index |
|---|---|---|---|
| Fluorinated fluid main circulation | Novec / synthetic hydrocarbon | MRB / MRC | 0.4–14 L/min, PEEK fully inert, pressure rating 6 MPa |
| Condensate return | Fluorinated fluid (low temperature section) | MRA / MRB | 0.1–4.8 L/min, fully magnetic zero leakage |
| Bypass filtration and purification | Fluorinated fluid + particulates | MPG / MRA | 2%–5% bypass ratio, PEEK resistant to HF |
| New fluid top-up | Pure fluorinated fluid stock | MPG | 40 μl/r, precise micro top-up |
| Periodic draining / fluid change | Aged fluorinated fluid | MRC / MRE | 0.8–48 L/min, quick-release and quick drain |
| CDU water-side circulation | Deionized water / glycol | MRE / MRF | 4–67 L/min, metal pump head optional |