General Equipment & OEM
General Equipment & OEM Integration: Precision Fluid Conveying for High Reliability and Extreme Duty
Magnetic coupling drive, reinforced PEEK gears, nano zirconia ceramic shaft — custom manufacturing to drawing, ODM platform derivation and non-standard special development.

In general equipment and OEM integration scenarios, a gear pump is usually not an independently delivered end product, it is a functional component embedded in a machine and running with the machine over the long term. Its failure does not only mean "a pump has to be replaced", it is more likely to appear as a machine shutdown, an occupied maintenance window, or even batch-level quality traceability. This is exactly why the evaluation criteria for fluid components in this segment differ from those of general industrial scenarios: flow and pressure are only the entry conditions, and what really decides the model selection is long-term reliability, the performance boundary under extreme duty, and whether the product can be redefined according to the installation space, the medium and the control logic of the complete machine.
01 · Three Core Requirements
02 · Seven Typical Process Points: Look at the Duty First, the Flow Second
On the same machine, the flow and the medium of different stations can differ by three orders of magnitude. The table below breaks down the duty characteristics and the key requirements on the pump by process point, and gives the recommended flow range; for the specific model, please match against the MR family quick-reference table in section 03.
| Process Point | Typical Duty Characteristics | Key Requirement on the Pump | Recommended Flow / Series |
|---|---|---|---|
| Circulation pressurization | Closed-loop long line, high flow resistance in micro channels, continuous pressure boost required | High working pressure difference, low pulsation, long-term continuous running | 0.8–48 L/min | MRC / MRE |
| Vacuum sampling | Sampling from a negative-pressure line, low-level extraction, quantitative transfer of the sample | Strong vacuum self-priming, zero leakage, no contamination of the sample | 1–2000 mL/min | MPG / MRA / MRB |
| Waste heat recovery | Heat transfer oil or coolant circulation, medium temperature fluctuates with the load | Wide temperature range, stable thermal expansion, temperature-resistant material | 4–67 L/min | MRE / MRF, MRV for compact stations |
| Lubrication | Point-to-point quantitative supply of lubricating oil or grease, with trace impurities and a wide viscosity span | Micro continuous supply, wear resistance, wide viscosity adaptability | 0.1–8 L/min | MRA / MRB / MRV |
| Micro spraying | Uniform micro application of release agent, rust inhibitor and coating additives | High accuracy at micro flow, no pulsation, good repeatability | 1–2000 mL/min | MPG / MRA |
| Leak detection | Quantitative supply of tracer liquid, calibration of standard leak holes, the leak-test circuit | Micro flow stability, repeatability, closed-loop controllability | 1–2000 mL/min | MPG / MRA, preferably with MDC |
| Pilot and trial-plant installations | Frequent changes of process parameters, multi-component ratios, data recording required | Wide turndown ratio, closed-loop automatic following, multi-channel synchronization | 1–10,000 mL/min | MDC + MR pump head |
03 · MR Family Quick-Reference Table: Define the Series by Flow
The first step of the model selection is to convert the duty into a target flow and then lock the series by the flow range; the second step is to check the medium, the temperature, the pressure difference and the viscosity to determine the material, the sealing and the motor; the third step is to check the installation space and the interface form to determine the structure and the customization items. The table below is the flow quick-reference of the whole MR family; the displacement options of each series can be further subdivided on this basis.
| Series | Flow Range | Pressure Difference (bar) | Main Matching Duty |
|---|---|---|---|
| MPG | 1–135 mL/min; 15–280 mL/min | Confirm by model | Micro spraying, leak detection, micro sampling |
| MRA | 100–2000 mL/min | 0.5–25 | Vacuum sampling, lubrication, pilot-plant ratios |
| MRB | 400–4800 mL/min | 0.5–25 | Lubrication, sampling, small-flow circulation |
| MRC | 0.8–14 L/min | 0.5–25 | Circulation pressurization, medium-flow cooling circuit |
| MRE | 4–48 L/min | 0.5–25 | Waste heat recovery, large-flow circulation pressurization |
| MRF | 8–67 L/min | 0.5–14.5 | Large-flow circulation, main circuit conveying |
| MRV | 0.2–8 L/min | 10 | Compact stations with limited installation space |
04 · When Closed-Loop Control Is Required, Choose the MDC
When the system pressure difference is unstable, the medium viscosity varies with temperature, the flow has to follow a process curve automatically, or multi-component synchronized ratioing and data recording are needed, open-loop speed control can hardly maintain the set flow over the long term. In that case the MDC micro metering pump control station can be stacked on the MR pump head. The MDC covers 1–10,000 mL/min, is compatible with the MPG, MRA, MRB and MRC pump heads, has a size of 310 × 200 × 240 mm, and provides three working modes: speed, flow and quantitative dispensing.
Its closed-loop logic is: the target flow is set on the touch screen, the flow meter and the pressure sensor collect the actual values online, the controller compares the deviation and automatically adjusts the motor speed so that the output returns to the set value; the fluctuation of the system pressure difference is compensated automatically by the closed loop instead of relying on repeated manual valve adjustment. If the project needs a complete-machine-level integrated platform, the desktop-type flow control system is available, integrating a filter, a gear pump, a servo motor, a Coriolis mass flow meter, a pressure sensor and valves, with a conveying accuracy of ±0.5‰, a response of 50–200 ms and a turndown ratio of 1:100, and supporting independent closed loops and synchronized ratioing from two components up to multiple components.
05 · Customized Delivery and the Selection Entry Point
The more complete the duty information submitted, the closer the initial proposal is to the final delivery. It is recommended to provide at the inquiry stage: the medium name and its physical and chemical properties, the target flow and the working pressure difference, the medium and ambient temperature, the viscosity range, the installation space and the interface form, the power supply and communication requirements, as well as special constraints such as cleanliness, explosion protection and zero leakage, and the estimated annual usage. The JONSN engineers then complete the platform selection or the feasibility assessment of a derivative, and output a verifiable selection scheme; at the prototype stage the customer can take part in the testing and the data review.