SCENARIO 01MPG + MRC
Single-Wafer Wet Cleaning: From "Soaking Evenly" to "Rinsing Precisely"
Single-wafer cleaning covers the most intensive chemical exchange in the front end: SPM (H2SO4/H2O2) for resist and organic removal, SC1 (NH4OH/H2O2/H2O) for particle removal, SC2 (HCl/H2O2/H2O) for metal removal, DHF/BOE for native oxide, plus ozone water and DIW final rinse. A complete single-wafer cleaning cycle is often completed in 30–60 seconds, covering spray, dwell and rinse.
The difficulty is not total volume but rhythm. Chemical ratio must be accurate — a deviation in volume ratio directly changes the reaction rate. Rinse flow must be stable — flow overshoot leaves watermarks on the wafer edge, insufficient flow leaves residue. Pump stop must be clean — the nozzle must not drip, or chemical spots appear on the next wafer. Strongly oxidizing media continuously attack seals and flow path materials.
Pump solution is division of labour: MPG on the low-flow constant-flow and ratio side, 1–135 mL/min for mL/min-level precision dosing; MRC on the high-pressure spray side, 0.8–14 L/min so that flow does not collapse when nozzle back pressure changes. Both use a PTFE/PEEK all-plastic flow path with no exposed metal, withstanding continuous oxidation by SPM and ozone water.
SCENARIO 02MPG
Developing: Flow Fluctuation Is Directly Converted into CD Deviation
TMAH 2.38% is the mainstream developer, with pH above 13. Developing is a process of chemical dissolution plus diffusion control; flow changes the boundary layer thickness on the wafer surface, ultimately appearing as CD deviation and line-edge roughness. By engineering experience, a ±2% fluctuation in developer flow can correspond to 1 nm or more of CD shift — at advanced nodes, this already consumes a significant part of the process window.
The develop step has three variables: concentration, temperature and flow. Concentration is handled by inline sensors and the replenishment system, temperature by heat exchangers, and flow is the one the pump is fully responsible for. The develop chamber also needs to switch between developer and DIW, so multi-head paralleling is a common architecture, with each channel controlled independently and free of interference.
Pump-side requirements concentrate on three points: flow repeatability, alkali resistance, switching response. The MPG series covers developer supply of 1–135 mL/min with ±0.3%–±0.5% flow accuracy and pulsation-free output; the flow path can be 316L or all-plastic for long-term immersion above pH 13. With parallel heads, the flow of each channel can be set independently, enabling scheduled switching between developer and rinse.
SCENARIO 03MRC + MPG
Etching: Material and Sealing Test under High-Pressure Circulation
The wet etch media spectrum is wide: HF and BOE for silicon oxide, H3PO4 for silicon nitride (working temperature up to the 160 ℃ class), HNO3/CH3COOH systems for polysilicon and metals, KOH/TMAH for single-crystal silicon anisotropic etching. Etch rate is highly sensitive to temperature and concentration, while circulation and spray uniformity in the tank determines whole-wafer consistency.
The supply characteristic here is "high flow + high back pressure + long continuous operation". The circulation line passes through filters, heat exchangers and spray headers, so terminal pressure drop is substantial; fluorinated media restrict material choice because of metal corrosion. The traditional approach uses a high-power centrifugal pump with bypass regulation, at the cost of imprecise metering and relatively high shear.
The role of the MRC series here is "high pressure and metering-capable": the 0.8–14 L/min range with high-pressure output maintains the set flow while the filter gradually clogs and back pressure rises; the zero-leakage magnetic coupling avoids the rapid failure of dynamic seals in hot fluorinated media. Etchant replenishment and additive metering are handled by MPG — together forming a "main circulation + precision dosing" combination.
SCENARIO 04MPG
CMP Slurry Micro Point-of-Use Dispensing: Low Shear Is Harder Than High Pressure
CMP slurry is a suspension of SiO2, Al2O3 or CeO2 nano-abrasives, with a pH span from strong acid to strong base, generally containing oxidizers and complexing agents. It has three typical failure modes: abrasive flushing wearing internal pump parts, particle agglomeration and settling in low-velocity regions, and high shear destroying the particle size distribution. All three cause the polish rate to deviate from the set value, or leave scratches and dishing on the wafer.
Point-of-use dispensing is now the more common supply form: instead of concentrating on high-flow supply, chemistry is dosed precisely per wafer and per segment near the polishing head, typically at 10–135 mL/min. With lower flow, shear and settling become more prominent — the longer the line and the lower the velocity, the more readily particles settle.
The technical point of the MPG series here is "low shear + no dead zones + wear resistance": involute gear profiles with optimized clearance keep the shear rate low, dead-zone-free flow passages avoid slurry stagnation, and gears can be specified in engineering ceramic to resist long-term nano-abrasive flushing. No exposed metal in the flow path keeps metal leaching at the 1 ppb level, preventing contaminated slurry from carrying metal onto the wafer.
SCENARIO 05MPG
Photoresist Micro Dispensing: Bubbles Are a Zero-Tolerance Item
Typical photoresist viscosity is 5–200 cP (i-line / KrF / ArF standard resists), while thick resists for packaging and MEMS reach 500–5000 cP. It simultaneously has three difficult properties: photosensitivity (no prolonged exposure to light or heat), solvent-based (PGMEA, PGME, cyclohexanone, ethyl lactate, strongly swelling toward sealing materials), and zero tolerance for bubbles.
Bubbles are the most direct risk here. Even micron-scale micro-bubbles, when they burst during the high-speed spinning of a coater, leave pinholes or comet defects on the wafer surface, directly appearing as pattern shorts or opens. Conventional diaphragm and bellows pumps tend to generate negative pressure during the suction stroke — and negative pressure is precisely the condition for cavitation and bubble generation.
The MPG series replaces the reciprocating suction structure with a positive-displacement gear pair, so no negative-pressure suction condition is created by principle; involute tooth forms with multi-tooth meshing make the output nearly continuous, avoiding thickness variation caused by pulsation; the dead-zone-free design pushes line residual below 0.1 mL — photoresist is expensive, and residue is both cost and a cross-contamination source during resist change. An optional temperature control module locks the resist temperature at ±0.1–0.5 ℃, so viscosity stays stable and film thickness stays stable.
SCENARIO 06MRC
Stripper High-Pressure Supply: High Temperature, High Viscosity and Long Lines
Resist stripper is based on NMP, sulfolane, MEA/DMSO systems, with working temperatures commonly at 60–90 ℃. Unlike developing and cleaning, stripper is mostly centrally supplied: from the chemical warehouse through long pipelines to the tool, with terminal filters and spray nozzles in between. Long lines, high viscosity and filter pressure drop combine, so back pressure easily exceeds the capability of conventional metering pumps.
Hot organic solvents are the "killer" of dynamic seals. O-rings and diaphragms in conventional pumps continuously swell and harden in this environment, with lifespans often only a few months — and once a leak occurs, hot stripper is both material loss and a safety hazard.
The MRC series targets exactly this duty: the 0.8–14 L/min range with high-pressure output is enough to overcome the pressure drop of long lines and terminal filters; magnetic coupling removes the dynamic seal and the isolation sleeve is a static seal, fundamentally removing the swelling and leakage path; the flow path can be specified with PTFE lining and engineering ceramic or corrosion-resistant alloy. For central supply systems, pressure margin means flow does not need to be chased manually with valves across the whole filter life cycle.