Semiconductors & ElectronicsSemiconductors & Electronics
Semiconductors & Electronics

Wafer Wet Process

2026-11-20
View:16
Applications · Wafer Wet Process Supply

Precision Chemical Supply for Wafer Wet Processes: Ultra-Pure Micro Metering and High-Pressure Supply with JONSN MPG & MRC

Coverage — single-wafer wet cleaning · developing · etching · CMP slurry micro point-of-use dispensing · photoresist micro dispensing · stripper high-pressure supply

JONSN MPG · 1–135 mL/min ultra-pure supply
JONSN MRC · 0.8–14 L/min high-pressure supply
Flow pulsation < 3%
Metal leaching < 1 ppb
ISO Class 5 wetted path
Zero-leakage magnetic drive
矩形 6备份 4.jpg

Wet Process: The "Liquid Foundation" of Patterning Accuracy

In front-end wafer manufacturing, wet processes carry out the vast majority of "surface preparation" and "pattern transfer" work. Cleaning removes particles and metal contamination; coating establishes the photosensitive layer; developing converts the mask pattern into the resist pattern; etching transfers the resist pattern into the film; CMP re-flattens the uneven surface; stripping clears away the photoresist that has done its job. The media used across these steps vary enormously — but the requirements placed on the supply system are highly isomorphic: flow must be stable, pressure must be sufficient, and no new contamination may be introduced.

Cleaning SC1 / SC2 / SPM / DHF
Developing TMAH developer
Etching HF / H3PO4 / BOE
CMP slurry SiO2 / Al2O3 / CeO2
Photoresist PGMEA series
Stripper NMP series
Batch Tank Processing
In batch tank processing, one bath of chemistry processes 25 wafers. Flow fluctuation is averaged out by the concentration and soak time of the whole bath.
Single-Wafer Processing
After the process shifted from batch tank to single-wafer handling, the requirement is amplified. Single-wafer processing handles one wafer at a time, and the dwell time of chemistry on the wafer surface is often only a few tens of seconds. The flow overshoot at start-stop, a single bubble in the line, and the flow drop caused by rising filter pressure drop all land entirely on that one wafer — there is no subsequent wafer to average it out.
矩形 6备份 5.jpg
The supply high pressure micro pump therefore changes from an "accessory" into "part of the process parameters". The basis for pump selection shifts from "can it pull the fluid" to "is the flow stable, is the shear low, does it bring metal ions, and does the flow collapse when pressure drops".

The Common Thresholds Behind Six Classes of Duty

1
Ultra-Purity and Low Leaching
The tolerance of advanced nodes for metal-ion contamination has already reached the ppt level. There should be no exposed metal in the wetted flow path, metal leaching must be controlled within 1 ppb, and the material system must align with ultra-purity requirements such as SEMI F57. This is not an option — it is the entry ticket to front-end processes.
2
Pulsation-Free Continuous Flow
Pulsation leaves periodic traces on the wafer surface — film thickness streaks, periodic variation of etch depth, polishing rate fluctuation. The multi-tooth meshing of a gear pump combined with positive displacement output suppresses flow pulsation to within 3% by structure, not by control compensation.
3
Low Shear
Photoresist is a polymer solution; shear breaks molecular chains and changes the molecular weight distribution. CMP slurry is a nano-abrasive suspension; shear destroys the particle size distribution and triggers agglomeration. Here shear is not an efficiency issue but a medium-performance issue — the D50 of the medium should not change between inlet and outlet.
4
Zero Leakage
HF, SPM and high-temperature stripper are both strongly corrosive and hazardous to people. Magnetic coupling removes the dynamic seal and replaces it with a static-sealing isolation sleeve, structurally eliminating the leakage path — and at the same time solving the swelling failure of dynamic seals in strong solvents.
5
Micro-Flow Precise Metering
Photoresist dispensing and CMP point-of-use dispensing often run at mL/min level, requiring a sufficiently small and sufficiently constant displacement per revolution, combined with a servo loop that converts speed accuracy into flow accuracy.
6
High-Pressure Stable Supply
Terminal nozzle back pressure, line loss along a long pipeline, and rising pressure drop after filter clogging all pull the flow down. Without pressure margin, flow decays together with filter life. This is exactly why "ultra-pure micro" and "high-pressure high-flow" need two product series, rather than one product with two ratings.

Six Typical Application Scenarios and Their Supply Requirements

SCENARIO 01MPG + MRC
Single-Wafer Wet Cleaning: From "Soaking Evenly" to "Rinsing Precisely"
Single-wafer cleaning covers the most intensive chemical exchange in the front end: SPM (H2SO4/H2O2) for resist and organic removal, SC1 (NH4OH/H2O2/H2O) for particle removal, SC2 (HCl/H2O2/H2O) for metal removal, DHF/BOE for native oxide, plus ozone water and DIW final rinse. A complete single-wafer cleaning cycle is often completed in 30–60 seconds, covering spray, dwell and rinse.
The difficulty is not total volume but rhythm. Chemical ratio must be accurate — a deviation in volume ratio directly changes the reaction rate. Rinse flow must be stable — flow overshoot leaves watermarks on the wafer edge, insufficient flow leaves residue. Pump stop must be clean — the nozzle must not drip, or chemical spots appear on the next wafer. Strongly oxidizing media continuously attack seals and flow path materials.
Pump solution is division of labour: MPG on the low-flow constant-flow and ratio side, 1–135 mL/min for mL/min-level precision dosing; MRC on the high-pressure spray side, 0.8–14 L/min so that flow does not collapse when nozzle back pressure changes. Both use a PTFE/PEEK all-plastic flow path with no exposed metal, withstanding continuous oxidation by SPM and ozone water.
SCENARIO 02MPG
Developing: Flow Fluctuation Is Directly Converted into CD Deviation
TMAH 2.38% is the mainstream developer, with pH above 13. Developing is a process of chemical dissolution plus diffusion control; flow changes the boundary layer thickness on the wafer surface, ultimately appearing as CD deviation and line-edge roughness. By engineering experience, a ±2% fluctuation in developer flow can correspond to 1 nm or more of CD shift — at advanced nodes, this already consumes a significant part of the process window.
The develop step has three variables: concentration, temperature and flow. Concentration is handled by inline sensors and the replenishment system, temperature by heat exchangers, and flow is the one the pump is fully responsible for. The develop chamber also needs to switch between developer and DIW, so multi-head paralleling is a common architecture, with each channel controlled independently and free of interference.
Pump-side requirements concentrate on three points: flow repeatability, alkali resistance, switching response. The MPG series covers developer supply of 1–135 mL/min with ±0.3%–±0.5% flow accuracy and pulsation-free output; the flow path can be 316L or all-plastic for long-term immersion above pH 13. With parallel heads, the flow of each channel can be set independently, enabling scheduled switching between developer and rinse.
SCENARIO 03MRC + MPG
Etching: Material and Sealing Test under High-Pressure Circulation
The wet etch media spectrum is wide: HF and BOE for silicon oxide, H3PO4 for silicon nitride (working temperature up to the 160 ℃ class), HNO3/CH3COOH systems for polysilicon and metals, KOH/TMAH for single-crystal silicon anisotropic etching. Etch rate is highly sensitive to temperature and concentration, while circulation and spray uniformity in the tank determines whole-wafer consistency.
The supply characteristic here is "high flow + high back pressure + long continuous operation". The circulation line passes through filters, heat exchangers and spray headers, so terminal pressure drop is substantial; fluorinated media restrict material choice because of metal corrosion. The traditional approach uses a high-power centrifugal pump with bypass regulation, at the cost of imprecise metering and relatively high shear.
The role of the MRC series here is "high pressure and metering-capable": the 0.8–14 L/min range with high-pressure output maintains the set flow while the filter gradually clogs and back pressure rises; the zero-leakage magnetic coupling avoids the rapid failure of dynamic seals in hot fluorinated media. Etchant replenishment and additive metering are handled by MPG — together forming a "main circulation + precision dosing" combination.
SCENARIO 04MPG
CMP Slurry Micro Point-of-Use Dispensing: Low Shear Is Harder Than High Pressure
CMP slurry is a suspension of SiO2, Al2O3 or CeO2 nano-abrasives, with a pH span from strong acid to strong base, generally containing oxidizers and complexing agents. It has three typical failure modes: abrasive flushing wearing internal pump parts, particle agglomeration and settling in low-velocity regions, and high shear destroying the particle size distribution. All three cause the polish rate to deviate from the set value, or leave scratches and dishing on the wafer.
Point-of-use dispensing is now the more common supply form: instead of concentrating on high-flow supply, chemistry is dosed precisely per wafer and per segment near the polishing head, typically at 10–135 mL/min. With lower flow, shear and settling become more prominent — the longer the line and the lower the velocity, the more readily particles settle.
The technical point of the MPG series here is "low shear + no dead zones + wear resistance": involute gear profiles with optimized clearance keep the shear rate low, dead-zone-free flow passages avoid slurry stagnation, and gears can be specified in engineering ceramic to resist long-term nano-abrasive flushing. No exposed metal in the flow path keeps metal leaching at the 1 ppb level, preventing contaminated slurry from carrying metal onto the wafer.
SCENARIO 05MPG
Photoresist Micro Dispensing: Bubbles Are a Zero-Tolerance Item
Typical photoresist viscosity is 5–200 cP (i-line / KrF / ArF standard resists), while thick resists for packaging and MEMS reach 500–5000 cP. It simultaneously has three difficult properties: photosensitivity (no prolonged exposure to light or heat), solvent-based (PGMEA, PGME, cyclohexanone, ethyl lactate, strongly swelling toward sealing materials), and zero tolerance for bubbles.
Bubbles are the most direct risk here. Even micron-scale micro-bubbles, when they burst during the high-speed spinning of a coater, leave pinholes or comet defects on the wafer surface, directly appearing as pattern shorts or opens. Conventional diaphragm and bellows pumps tend to generate negative pressure during the suction stroke — and negative pressure is precisely the condition for cavitation and bubble generation.
The MPG series replaces the reciprocating suction structure with a positive-displacement gear pair, so no negative-pressure suction condition is created by principle; involute tooth forms with multi-tooth meshing make the output nearly continuous, avoiding thickness variation caused by pulsation; the dead-zone-free design pushes line residual below 0.1 mL — photoresist is expensive, and residue is both cost and a cross-contamination source during resist change. An optional temperature control module locks the resist temperature at ±0.1–0.5 ℃, so viscosity stays stable and film thickness stays stable.
SCENARIO 06MRC
Stripper High-Pressure Supply: High Temperature, High Viscosity and Long Lines
Resist stripper is based on NMP, sulfolane, MEA/DMSO systems, with working temperatures commonly at 60–90 ℃. Unlike developing and cleaning, stripper is mostly centrally supplied: from the chemical warehouse through long pipelines to the tool, with terminal filters and spray nozzles in between. Long lines, high viscosity and filter pressure drop combine, so back pressure easily exceeds the capability of conventional metering pumps.
Hot organic solvents are the "killer" of dynamic seals. O-rings and diaphragms in conventional pumps continuously swell and harden in this environment, with lifespans often only a few months — and once a leak occurs, hot stripper is both material loss and a safety hazard.
The MRC series targets exactly this duty: the 0.8–14 L/min range with high-pressure output is enough to overcome the pressure drop of long lines and terminal filters; magnetic coupling removes the dynamic seal and the isolation sleeve is a static seal, fundamentally removing the swelling and leakage path; the flow path can be specified with PTFE lining and engineering ceramic or corrosion-resistant alloy. For central supply systems, pressure margin means flow does not need to be chased manually with valves across the whole filter life cycle.

Six Selection Decision Points

Point 01
Which Flow Rate Band
Duty measured in mL/min takes MPG; duty measured in L/min takes MRC. For the boundary band of 100–135 mL/min, decide by pressure requirement first — high back pressure and long lines point towards MRC.
Point 02
Check Back Pressure at Worst Case
Terminal nozzle pressure, end-of-life filter pressure drop, line loss along the pipeline, and liquid level difference — stack all four, then leave margin. Selecting on the pressure drop of a new filter is the most common mistake in central supply systems.
Point 03
Medium Chemistry Determines the Material Combination
Strongly oxidizing (SPM), strong alkali (TMAH/KOH), fluorinated strong acid (HF/BOE) and organic solvents (NMP/PGMEA) each correspond to different flow path and sealing configurations — one material set cannot cover every case.
Point 04
Write Cleanliness and Leaching Grades into the Specification
Metal leaching < 1 ppb, ISO Class 5, internal surface Ra ≤ 0.4 μm, and support for CIP online cleaning — these decide whether the pump can enter the front end.
Point 05
Viscosity and Temperature Control Are the Same Problem
Viscosity is exponentially sensitive to temperature, so temperature control accuracy is effectively flow accuracy. Thick resists and high-temperature stripper in particular require the heating jacket and insulated piping to be considered together.
Point 06
Control Method Must Interface with the Tool
Servo drive with 0–10 V / 4–20 mA / pulse interface is required to achieve per-wafer metering and closed-loop flow. A pump with on/off control only cannot deliver its accuracy in single-wafer processing.

Please Contact Us!

ADDRESS

Building A3, Qiuyue Science and Technology Park, Ganzhou Economic and Technological Development Zone, Jiangxi Province

Tel.

0086-21-34720020

Follow Us

CopyRight © 2026 - Shanghai JONSN Fluid Equipment Co., Ltd.  All rights reserved  Sitemap All tags  Designed by Zhonghuan Internet
WHAT ARE YOU LOOKING FOR?
*
This field is required
Total quantity you need
*
This field is required
*
This field is required
Email format error
Due to email instability, you might miss our correspondence. Please provide your phone number for alternative contact.
This field is required
Telephone information is wrong!
Send Message
Get Custom Fluid Dosing Selection Solution
Starting a new project? Contact us for tailored pump solutions — from inlet specs and pipe sizing to motor matching and drawings — designed to fit your working conditions and accelerate your R&D cycle.
Company Name
*
This field is required
Email
*
This field is required
Email format error
Phone
This field is required
Telephone information is wrong!
WhatsApp
Message
*
This field is required
Send Message