Liquid CoolingLiquid Cooling
Liquid Cooling
HomeCaseLiquid CoolingEV Thermal Management

EV Thermal Management

2026-11-25
View:8
Applications · Liquid Cooling · New Energy Vehicle Thermal Management

Precision Conveying for the Liquid Cooling Circuit of New Energy Vehicle Thermal Management

Applicable links: battery pack cooling circuit, e-drive and power electronics cooling, vehicle thermal management bench testing — recommended series: JONSN MRA / MRB / MRV micro magnetic gear pumps

MRA · Micro precision circulation
MRB · Multi-branch parallel distribution
MRV · Compact integrated module
Magnetic coupling static sealing, zero leakage
−20~100 ℃, custom −40 ℃ / 160 ℃
−40 ℃ cold start, 15 g vibration, IP67
Compact build, only 99 mm overall length
矩形 6备份 16.jpg
Content Summary

The thermal management system of a new energy vehicle brings the heat of the battery pack, the e-drive, the power electronics and the passenger cabin into one liquid cooling circuit, and the flow distribution accuracy of the coolant directly affects the cell temperature difference, the junction temperature of the power devices and the energy consumption of the whole vehicle. The circulation pump in the circuit has to withstand road vibration and cold start for the long term, and at the same time be embedded in the space-constrained chassis and the test bench, while keeping a reliable seal over the whole vehicle life cycle. The JONSN MRA / MRB / MRV series micro magnetic gear pumps, with magnetic coupling static sealing, a wide-temperature material system and a compact structure, cover the small-flow precision circulation from bench calibration to the cooling circuit of the complete vehicle.

I. Three Duty Scenarios and Their Core Pain Points

Scenarios
Duty Scenario · Typical Medium · Duty Characteristics · Key Requirement on the Circulation Pump
Duty ScenarioTypical MediumDuty CharacteristicsKey Requirement on the Circulation Pump
Battery pack cooling circuitGlycol water solution, deionized waterHigh flow resistance in the cold plate micro channels, multiple branches in parallel, cold start at low temperature, limited installation space on the chassisSmall flow with high linearity, stable pressure difference, wide temperature range, zero leakage, compact structure
E-drive and power electronics coolingGlycol water solution, insulating coolantPower surges bring fast changes in heat load, continuous road vibration, located next to the high-voltage electrical compartmentVibration resistance, fast flow adjustment, reliable sealing, good medium compatibility
Vehicle thermal management bench testingGlycol water solution, fluorinated liquidMulti-duty cycling, frequent start-stop, the flow has to be accurately reproduced and acquiredNo pulsation, adjustable linear flow, good batch consistency, closed-loop control support
Battery pack cooling circuit · E-drive and power electronics cooling · Vehicle thermal management bench testing
Battery pack cooling: "distribute evenly"
The difficulty of the battery pack cooling circuit lies in "distributing evenly". The cold plate flow passages are long and thin and the branches are in parallel, so a low flow in any branch forms a local hot spot, which then amplifies the cell temperature difference. Centrifugal pumps drift in flow when the system resistance changes with temperature and valve opening, and the mechanical shaft seal has a leakage risk under long-term vibration; once the coolant enters the high-voltage electrical area, the consequences often exceed the thermal management itself.
E-drive and power electronics: "keep up"
The difficulty of the e-drive and power electronics circuit lies in "keeping up". During acceleration, climbing and fast charging the heat load rises within seconds, so the circulation pump has to adjust the flow quickly following the control command, while at the same time withstanding the continuous vibration from the road and the powertrain. The pump unit is usually placed close to the high-voltage components, so a small size, a reliable seal and no additional leak point in operation matter more than simply pursuing a large flow.
Bench testing: "reproduce"
The difficulty of the bench testing link lies in "being able to reproduce". Thermal management calibration requires repeated data comparison under multiple duties of high and low temperature, varying flow and frequent start-stop; if the pump output has pulsation, or the flow characteristics differ between batches, the test data can hardly be compared horizontally and the calibration cycle is extended.

II. From Duty Requirements to Technical Implementation

Vibration
Vibration resistance points to the structure, not to a thicker casing
Cancelling the rotating shaft seal that runs through the pump body and using magnetic coupling to transmit the torque, replacing the dynamic seal with a static O-ring sealing, reduces the wear points and the leak points under vibration from the structure itself. JONSN adopts a one-piece pump body with a static sealing ring, the gear cavity is machined in one operation on a CNC, and the clearance between the gears and the cavity is guaranteed by the machining accuracy; the MRV series goes further with a cast steel one-piece pump body, whose structural strength and mounting rigidity suit a vibration environment better.
Temperature
A wide temperature range needs both material and drive
The gears inside the pump use high-strength wear-resistant PEEK, and the shaft and sliding bearings use a zirconia nano-ceramic and modified PEEK composite ceramic formulation, lubricated by the coolant itself, so no oil seal and no grease are needed and there is no seizing at low temperature because a lubricant has solidified. The standard medium temperature range is −20~100 ℃, and a −40 ℃ low-temperature or 160 ℃ high-temperature version can be customized per project; the matching automotive-grade brushless driver works continuously at an ambient temperature of −40~70 ℃ and provides over-temperature and over-current protection.
Compactness
The MRV series is built for real vehicle and bench installation
The MRV series is designed for equipment cavities and installation spaces with limited room; with a 24 V / 150 W shielded brushless motor, the overall length of the pump and motor is about 99 mm. The interface forms — flange, quick-connect and clamp — and the 0° / 90° / 180° inlet and outlet directions can be selected to match the pipe layout, which makes it easy to embed the unit in the chassis, in the cooling module and in the bench cabinet.
Reliability
Verifiable and reproducible
The positive-displacement principle of a positive-displacement pump brings a continuous, pulsation-free output, and combined with a brushless or servo drive it enables a linear adjustment of the speed and the flow, which is convenient for the thermal management controller to run a PID closed loop and is also good for the reproduction of bench test data. For automotive-grade applications, the JONSN gear pumps have completed verification testing of −40 ℃ cold start, 15 g vibration and IP67 protection in new energy vehicle cooling projects; the whole series has passed ISO 9001:2015 (TÜV Rheinland), FDA and RoHS certification. The acceptance indices of a specific project are subject to the technical agreement confirmed by both sides and to the measured report.
MRV compact structure: about 99 mm overall length with a 24 V / 150 W shielded brushless motor

Please Contact Us!

ADDRESS

Building A3, Qiuyue Science and Technology Park, Ganzhou Economic and Technological Development Zone, Jiangxi Province

Tel.

0086-21-34720020

Follow Us

CopyRight © 2026 - Shanghai JONSN Fluid Equipment Co., Ltd.  All rights reserved  Sitemap All tags  Designed by Zhonghuan Internet
WHAT ARE YOU LOOKING FOR?
*
This field is required
Total quantity you need
*
This field is required
*
This field is required
Email format error
Due to email instability, you might miss our correspondence. Please provide your phone number for alternative contact.
This field is required
Telephone information is wrong!
Send Message
Get Custom Fluid Dosing Selection Solution
Starting a new project? Contact us for tailored pump solutions — from inlet specs and pipe sizing to motor matching and drawings — designed to fit your working conditions and accelerate your R&D cycle.
Company Name
*
This field is required
Email
*
This field is required
Email format error
Phone
This field is required
Telephone information is wrong!
WhatsApp
Message
*
This field is required